3-58 Customer Programming Software (CPS)
6866537D87-F Chapter 3 - MTM800 Product Information Manual September 2008
16.11 Key Fail Indication Timer
This option is used to set the periodic time interval for the Key Fail Alert.
See Paragraph 16.1 "Periodic End-To-End Key Failure Notice" above.
16.12 Re-Key Ongoing Timer
This option is used to set the response time interval after which the user will be alerted that no
response has been received from the KMF to a re-key request.
16.13 Re-Key Completion Timer
The entry in this field defines the time after which the user is alerted when a re-key request has not
been completed.
16.14 Mandatory On Relaxation
This check box determines whether or not a received clear call is Accepted/Unmuted or Rejected/
Muted when the default mode of the accosiation is Mandatory On.
16.15 Infinit End-To-End Key Retention
Selecting this option enables the terminal to permanently store encryption keys even when the
battery is removed.
16.16 End-To-End Encryption in Class of MS
This field indicates whether the terminal is E2E capable or not. This is a sub-element of Class of
terminal Information element.
This field is set to Enabled in power-up if the terminal is equipped with the UCM.
Turn the check box on (Enable/Encrypted) or off (Disable/Clear) by clicking in the check box.