3-84 Customer Programming Software (CPS)
6866537D87-F Chapter 3 - MTM800 Product Information Manual September 2008
22 Audio Parameters
The following sub menus are available:
Hot Mic
AGC
Ambience Listening
Volume Settings
Mic Settings
22.1 Hot Mic
The following screen shot shows the features available on the MTM800.
This sub menu has 3 editable options.
22.1.1 Hot Mic Pending Timer
This option is used to set the time during which the phone will try to get talk permit after entering
Emergency Mode.
Timer range is 0 and 10 - 30 seconds, the default setting is 30 seconds
22.1.2 Hot Mic Duration Timer
This option is used to set the time period during which the phone has talk permission after entering
Emergency Mode and the user is able to initiate an emergency group call without using the PTT
button.
Timer range is 0 and 30 -1800 seconds, the default setting is 300 seconds
22.1.3 Hot Mic Gain Delta
This option is used to set the mic gain when the terminal enters emergency mode.
The levels are in dBs referenced to the normal mic gain setting
The selectable levels are:
-3 – the gain is lower than the default gain of the microphone.
0 – the gain is the default gain of the microphone.