Data Services 3-113
September 2008
Chapter 3 - MTM800 Product Information Manual 6866537D87-F
• Allowed - Status will be sent without disconnect the call.
The default is set to ’Allowed’.
To select the option, put the pointer into the field value, click on the arrow.
26.4.18 Mail Out During Group Call
Defines option for sending a text message during active group or broadcast call.
The options are:
• Not Allowed - Not allowed to send text message while there is an active group call.
• Leave Call to send Mail - The call will be disconnected and the text message will be sent.
• Allowed - Text message will be sent without disconnect the call.
The default is set to ’Allowed’.
To select the option, put the pointer into the field value, click on the arrow.
26.4.19 Default Data Russian Encoding Scheme
Indicates which Russian SDS encoding scheme will be used.
There are 2 encoding schemes available to encode the SDS message:
• ISO-8895-5 Latin / Cyrillic (8-bit)
• Unicode (16-bit)
To select the option, put the pointer into the field value, click on the arrow, and drag the pointer to the
desired option.
When the flag is set to ISO/IEC 8859-5 (0x05), the radio will transmit a SDS message at most 140
characters long. When the flag is set to Unicode (0x1A), the radio will transmit a SDS message at
most 70 characters long.
26.5 PEI Parameter
Lists the parameters related to the Peripheral Equipment Interface (PEI) feature.
26.5.1 Baud Rate
Selects the transmission rate at which data flows between DTE (e.g. computer) and DCE (i.e. this
TETRA terminal). Baud rate is the number of bits of information, including "control" bits that are
transmitted per second.
The possible values are 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200 bps. The
value chosen here will be the default value at radio power-up. The default value is 9600 bps.
To select the option, put the pointer into the field value, click on the arrow, and drag the pointer to the
desired option.