3-64 Customer Programming Software (CPS)
6866537D87-F Chapter 3 - MTM800 Product Information Manual September 2008
18.2.2 Emergency Call
This option is used to enable/disable the emergency call feature in the terminal.
Also called PPC Group Call, which is an outgoing group call with emergency call priority made from
Emergency mode only.
To send an emergency call, the user enters Emergency mode to initiate an Emergency Call and
presses the PTT, unless the Hot Mic feature is enabled.
See related fields:
Paragraph 22.1 "Hot Mic"
18.2.3 Emergency Console Acknowledge
This feature determines whether or not the terminal should expect an acknowledgement to an
Emergency Alarm or Priority Dialing (Priority Dispatch Number) from the RCM (Radio Control
Manager)/Dispatcher.
The feature is Enable/Disable by clicking in the check box.
18.2.4 Emergency Switch Power Up
This feature enables the terminal to be powered up and enter emergency mode by an external
source that provides the necessary emergency input.
18.2.5 Emergency Call Type
The terminal is able to set up an emergency call to either a Group or Private address (ISSI).
18.2.6 Emergency Started Timer
This defines the period of time in milliseconds that the user must keep the emergency button
pressed for the terminal to enter emergency mode.
The programmable range is 1 - 5000 msecs.
The default is 500 msecs
Related field is:
Paragraph 18.2.1 "Emergency Alarm"
18.2.7 Emergency Cancel Timer
This defines the period of time in milliseconds that the user must keep the relevant button pressed
for the terminal to exit emergency mode.
Note: Ensure that Emergency Alarm or Emergency Call is enabled to activate this timer.
The range for this option is 250 - 3750 msecs. The default is 2000 msecs.