Speech output & sounds
Page 210
PROFI TX
If a sensor triggers an alarm, it is announced immediately even if it is not enabled
for announcing. As long as the alarm persists, it is included in the sequence of the
announcement block in accordance with its sensor address.
When a control is used for setting the volume (see section 4.3.1 "Volume" on
page 95), the announcement sequence can be restarted by muting the volume
and then turning it up again.
8.7 Announcing altitude
If your model includes an altitude sensor, you can have the device announce the
altitude. 4 options are available:
1. Announcement at intervals
The altitude is announce at intervals of 3 to 30 seconds.
2. Announcement by grid
A grid is applied to the altitude values. When the altitude changes to a different
field in the grid, the altitude is announced. This method is activated when the
announcement interval is switched off.
Altitude
Grid
up to 100m
25m
up to 350m
50m
400m and higher
100m
3. A switch can be assigned to the altitude announcement (see section 4.3.7.3
"Assign.Switches" on page 109). The altitude is announced immediately after
the announcement feature is switched on. Then, the altitude is announced at
intervals or by grid as long as the switch is set to ON. Use a button to call up
the altitude if you do not wish to have the altitude announced continually.
4. The volume of the variometer tone is configured separately. You can also
assign a control (see section 4.3.1 "Volume" on page 95). When you mute the
variometer volume and then turn it up again, the altitude is announced once.
Refer to section 4.3.5.1 "Vario. & Altitude" on page 102 for more information.