Cash Acceptor
Cleaning Sensors
11-24 NCR Personas M Series 5887 Operator Manual
Main Transport Unit (Area
Two)
11
To clean the sensors in this area of the main transport unit, proceed
as follows:
1 Using the compressed air and tube attachment, insert the tube
approximately 10 cm (4 in.) into the areas shown below.
2 Apply compressed air to the four prism ends under the top
bracket.
3 Apply compressed air to the four sensor lenses along the top
surface of the lower bracket. There are eight lenses/prism ends
to clean in total.
4 Close the main transport unit door.
Clean four lenses
on lower bracket
Clean four prism ends
under the top bracket