Error Reporting
How Errors in the PC Module Are Reported
NCR Personas M Series 5887 Operator Manual 2-3
How Errors in the PC Module Are
Reported
2
The reporting system does not report on the operator panel if a fault
has occurred on one of the boards in the PC module.
The boards in the PC module are tested during power-up and at
reset. If a fault is detected on one of the components of the PC
module, the Light Emitting Diode (LED) will be illuminated red.
The following table gives a summary of the LED colour code.
The location of the LED is different in the two types of PC module as
shown in the following illustration:
Note: In some designs of ATM the PC module is fitted in a
horizontal position.
If the LED is unlit or illuminated red after power-up or system reset,
call your customer engineer.
LED Colour Result Of Test
AMBER TEST STILL EXECUTING
RED TEST FAILED
GREEN TEST PASSED
UNLIT NO POWER TO MODULE