Chapter 5: Programming 5-57
Timers
NOTE:
NCR suggests that you do not set the Active Time
parameter to 0. Leaving the laser light on all the time reduces
its life expectancy.
Lockout Time
(Milliseconds)
A
350
8
450
0
600
1
750
2
900
3
1050
4
1200
5
1350
6
1500
7
Restart
Lockout Timer
B
Active Time
(Minutes)
C
Off
0
On
1
0
0
15
1
30
2
60
3
F
0
Enable
1
900ms
Lockout Timer
Restart Limit
Disable
27550
A
Your Program
Timers
1 2
Lockout
Time
B
Restart
Lockout
Timer
C
Active
Time
F
Timers
1 2
900ms lockout timer
restart limit
NOTE:
Direct Entry Only.
If the Restart Lockout Timer [B] is set to OFF,
the 900 ms Lockout Timer Restart Limit [F]
has no effect.