5-6  Chapter 5: Programming 
Programming Description 
The 7893 can be remotely programmed from its attached host terminal with no local 
intervention. To achieve this, special host terminal software (NCR RealPOS Scanner Tool 
Suite) must be purchased from NCR. This section describes programming a scanner with 
special bar code tags. 
Programming the 7893 consists of setting programming parameters to match specific needs. 
This is accomplished by scanning a specific sequence of programming tags. The factory sets 
most programming parameters to default values or values originally specified. In most 
installations, few, if any, programming changes need to be made. 
Creating the Program 
Creating a program consists of three basic steps. Details of these steps are given in various 
areas of this programming information. 
Write the Program 
1.  Identify requirements. The first thing is to determine the requirements of the 7893 
installation. This includes information about the communications protocol, the types of bar 
codes to be scanned, the use of good read tones, and scanner time–outs. 
Note:  NCR does not control or specify the NCR scanner configuration required to 
support specific Host Terminal Software unless you are using NCR Host Terminal 
Software.  You should consult with your Host Terminal Software vendor or reseller to 
determine the correct configuration for your NCR scanner. 
2.  Complete the programming worksheets. Using the descriptions contained in this document, 
complete each programming worksheet. Write the entries of the program in the space 
provided. Refer to the “Programming Worksheet” section in Chapter 5 for specific 
information about each parameter. 
Enter the Program 
1.  Enter the programming mode. Scan the Program Mode tag. This must be the first tag 
scanned after supplying power to the  
7893 (or the first tag after scanning the Reset tag). 
2.  Enter the parameters for each specific program. Scan the two Hex tags to select a specific 
program, and then enter all parameter data for it. After all the information has been 
entered, the 7893 returns to programming mode. Repeat this procedure for each specific 
program that needs to be changed. 
Note:  A specific program does not need to be entered if its associated programming is 
already correct. 
Save the Program 
1.  Scan the Save and Reset tag. When the Save and Reset tag is scanned, the scanner saves 
all programming parameters entered. This becomes the new scanner program. The scanner 
goes through initial startup and operates using the new program.