Release 6.0 396
User Guide Appendix F How to Set/Check Application Server (Linux) (iSCSI)
e. Execute the following commands.
iscsiadm -m node --targetname <target name
specified in step /a/> -p <target IP addresss
succeeded to log on in step /1/> --op update -n
node.session.auth.authmethod -v CHAP
iscsiadm -m node --targetname <target name
specified in step /a/> -p <target IP addresss
succeeded to log on in step /1/> --op update -n
node.session.auth.username -v <initiator name>
iscsiadm -m node --targetname <target name
specified in step /a/> -p <target IP addresss
succeeded to log on in step /a/> --op update -n
node.session.auth.password -v <CHAP password for
the initiator>
f. If you use mutual CHAP authentication, execute the following
commands.
iscsiadm -m node --targetname <target name
specified in step a.> -p <target IP address
succeeded to log on in step 1.> --op update -n
node.session.auth.username_in -v <target name
specified in step a.>
iscsiadm -m node --targetname <target name
specified in step a.> -p <target IP address
succeeded to log on in step a.> --op update -n
node.session.auth.password_in -v <CHAP password for
the target>
g. Execute the following command.
(If there are two or more IP addresses succeeded to log on, repeat
the steps e-g)
iscsiadm -m node --targetname <target name
specified in step a.> -p <target IP address
succeeded to log on in the step a.> -l
* If you use three or more disk arrays, repeat the procedures in steps
a-b repeatedly, and then perform the procedure in step c for the last
disk array unit. And then perform the procedure the steps d–g
repeatedly for each disk arrays you have done the procedures in step
a-b.)