EasyManua.ls Logo

NEC Storage M100 Series - Confirmation Using Guest os

NEC Storage M100 Series
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Release 6.0 423
User Guide Appendix H How to Set/Check Application Server (VMware) (iSCSI)
H.2.3 Confirmation Using Guest OS
Perform the following steps to confirm that the logical disks are recognized by the guest operating
system:
Confirmation in Windows Environment
1. Select Administrative Tools > Computer Management > Disk Manager to start.
2. Click Disk drives and check the number of logical disks (No. of logical disks assigned to server ×
No. of access paths from server to individual logical disks) and the respective disk drive names
(NEC DISK ARRAY SCSI Disk Device).
3. Open Disk Management and check the number of logical disks (number of logical disks assigned
to server).
Confirmation in Linux Environment
Run the following command to check the number of logical disks (No. of logical disks assigned to
application server × No. of access paths from application server to individual logical disks) and the
respective vendor and model names (NEC, DISK ARRAY).
If nothing is shown, check the software iSCSI Initiator settings for the
ESX Server environment, the server-Storage connections, NIC driver
settings and so on.
# cat /proc/scsi/scsi
If nothing is shown, check the software iSCSI Initiator settings for the ESX
Server environment, the server-Storage connections, NIC driver settings and
so on.

Table of Contents