NEC Storage M100 Series - Table 1-8: Host Port Status

NEC Storage M100 Series
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Release 6.0 50
User Guide Chapter 1 Overview
Lit Not lit
- - Starting up or rebooting.
Lit
Lit 1
second
Not lit 1
second
- - Waiting for the disk enclosure behind the given
enclosure to be powered on.
Lit Lit - - Failure has occurred.
Flashing
fast
Lit - -
Failure has occurred (log collectable).
Lit 1
second
Not lit 1
second
Lit - -
Retrying as disk enclosure shortage has been
detected.
Disk Port blocked.
Lit 1
second
Not lit 1
second
Flashing
fast
- - Updating firmware online.
- - Lit - The device is selected.
- - - Lit Detected BBU failure.
- - - Flashing Warning for the end of the BBU life cycle
Table 1-7: Status Display LED
(5) Ready
LED
(6) Fault
LED
(7) ID
LED
(8) BBU
LED
StatusGreen Orange Blue Orange
Table 1-8: Host Port Status
Host port Status
(9) Link LED (L) (green) Lit = linkup
Not lit = link down
(10) Active LED (A) (green) Lit or flashing = I/O access
Link/Active flashing together Flashing in a cycle of 2 seconds = Off line
Flashing in a cycle of 1 second = Powering off
Other than above = Invalid port settings