Release 6.0 82
User Guide Chapter 3 Installing the Disk Array System
1. Check the power.
Make sure the power of the disk array unit is off.
2. Connect the application server.
Insert the connector on one end of an FC cable (LC-LC cable) into a host connection port (HPx) on
the controller (CONT0 or CONT1) in the disk array unit until the connector clicks. The connectors on
both ends of an FC cable have the same shape.
Connect the connecter on the other end of the FC cable to the connecter of a host bus adapter
installed on the application server. In the same way, connect the other controller to the connector on
another host bus adapter.
For iSCSI Port Connection
See the "Preparation" section in one of the following sections:
Section C.1: Initializing Application Server (on Windows)
Section E.1: Installing NEC Storage Manager Agent Utility (on Linux)
Section H.1: Initializing Application Server (on VMware)
If you press an FC-cable connector hard when inserting it, the end face of
the cable may be scratched and light output may be decreased, which
may cause malfunction.