Loading...
3-87 NWA-033623-001 Rev.8.1
91ch3001.fm
COMMAND CODE
TITLE:
BASIC SERVICES
08
BASIC SERVICE: 1800-1872
: Default
BASIC SERVICE SETTING DATA
1800 Printout by Direct Data Entry
[8300R3]
0
1
Available
Not available
1801 Printing format of Direct Data Entry
[8300R3]
0
1
Format2
Format1
1817 Whether to send Check Out Outgoing Call Report (FTC=16,
FC=C) to PMS when guest station is engaged in an outgoing
call at check out
[8300R3]
0
1
Not sent
To send
1818 Whether to send Check Out Message Waiting ON/OFF Report
(FTC=16, FC=5/6)
[8300R3]
0
1
To send
Not sent
1819 Selection of message for Station Message Detail to be sent to
PMS
[8300R3]
0
1
FTC=14, FC=2
FTC=54, FC=1
1820 Selection of message for Message Waiting Lamp ON/OFF
changed by PBX to be sent to PMS
[8300R3]
0
1
FTC=13, FC=3/4
FTC=53, FC=2
1821 Provide parity LRC to transmission for PMS (Attach BCC to
messages)
[8300R3]
0
1
Not provided
To provide
1856 Ringing on Suite Room station
[8300R5]
0
1
Ring master station only
Ring all stations
NOTE: Sub station can be received an incoming call when this data is set to “0”.
1861 Setting of Room Cut Off when Room Status in recovery room
data notification (FTC=57, FC=1) is between 3 and 9
[8300R5]
0
1
To set
Not set
NOTE: This data is effective only when CM04 Y=01>10 is set to “0”.
1864 DSS console key for switching Check Out
[8300R5]
0
1
Available
Not available
NOTE: This data is effective only when CM04 Y=01>10 is set to “0”.