3-570 NWA-033623-001 Rev.8.1
91ch3006.fm
COMMAND CODE
TITLE:
EVENT OCCURRENCE NOTICE BUTTON ASSIGNMENT
9B
FUNCTION:
This command is used to provide the event occurrence notice button. When the offices with CCIS via
IPT (P2P CCIS) connection SIP trunk connection are disconnected due to a fault occurrence, the link
down can be notified to the Multiline Terminals that are connected to the offices. Also the Units (except
Main Unit) are disconnected due to a fault occurrence, the link down can be notified to the Multiline
Terminals that are connected to the units.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST
EXE
+
++
+
9BY
DATA
DE
EVENT OCCURRENCE NOTICE
+
(1 digit)
++
DE
LINK DOWN NOTICE FOR
(4 digits)
CCIS/SIP TRUNK/UNITS
BUTTON NUMBER
: Default
NOTE: Link down notice (02-50) corresponds to the Unit No. 02-50 (except Main Unit).
Y 1ST DATA SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
0 Link down notice for
CCIS/SIP trunk/
Units to the Event
Occurrence Notice
button
XX ZZ XX: 01-64: Event
Occurrence
Notice Button
No.
ZZ : 00: Link down
notice for CCIS
02-50: Link
down notice for
Units (except
Main Unit)
51: Link down
notice for SIP
NOTE
0
1
To notify
Not notified
CM90 Y=00:
F1600-F1663
CM9B