3-693 NWA-033623-001 Rev.8.1
91ch3008.fm
COMMAND CODE
TITLE:
LINE/TRUNK MEMORY/ALARM MEMORY READ
F5
FUNCTION:
This command is used only for maintenance.
DO NOT USE this command without the assistance of a NEC engineer.
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST + +F5Y
1ST DATA
(1-15 digits)
+ DE + DE
Y1ST DATA
READOUT DATA
(STATUS INFORMATION)
REMARKS
0
fX
fXXXXXXXX
f: Status Memory Block number
(0-3)
Single Line station/Virtual Line
station number (1-8 digits)
X: 0-9, A (*), B (#)
Basic memory dump data of
station/trunk
fFX
fFXXXXXXXX
f: Status Memory Block number
(0-3)
Multiline Terminal number
<X-XXXXXXXX>
represents My Line number
fD000
fD511
f: Status Memory Block number
(0-3)
Trunk number
fEEX
fEEXXXXXXXX
f: Status Memory Block number
(0-3)
PS Line station number
<X-XXXXXXXX>
fEFX +
+ B
fEFXXXXXXXX + + B
f: Status Memory Block number
(0-3)
ISDN Line station number
<X-XXXXXXXX>
B: B channel number (0/1)
1
XXYYZZ Physical Port No.
XX: Unit number (01-50)
YY: Slot number (01-18)
ZZ : Circuit number (01-32)
Basic memory dump data of
station/trunk
Continued on next page
~
~
~
~
,
~
,
CMF5