3-410 NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE
TITLE:
ROOM STATUS CODE
4B
FUNCTION:
This command is used to assign the functions for each Room Status Code which is dialed from a guest
room or a Front Desk Terminal.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
+ 4BYY + +ST DE
2ND DATA
(1 digit)
1ST DATA
(3 digits)
+ + + EXE
DE
: Default
Y
1ST DATA 2ND DATA
RELATED
COMMAND
DATA MEANING DATA MEANING
00 X00 Room Cutoff set/reset
X: Room Status Code 1-8
1
2
NONE
To set
To reset
Not available
X01 Do Not Disturb set/reset
X: Room Status Code 1-8
1
2
NONE
To set
To reset
Not available
X02 Wake Up Call reset
X: Room Status Code 1-8
1
NONE
Available
Not available
X03 Message Waiting set/reset
X: Room Status Code 1-8
1
2
NONE
To set
To reset
Not available
X05 Room Status Code dialing
from guest room is allowed
X: Room Status Code 1-8
1
NONE
Allow
Not allowed
NOTE: This data is not effective when CM04 Y=01>10: 0 (Control method for Hotel Feature
is set to PMS).