3-571 NWA-033623-001 Rev.8.1
91ch3006.fm
COMMAND CODE
TITLE:
DESI-LESS LCD
9C
FUNCTION:
This command is used to set characters displayed on DESI-less LCD of DT300/DT700 Series.
[8300R2]
PRECAUTION:
This data setting is valid by resetting DT300/DT700 Series or executing CM12 Y=29.
ASSIGNMENT PROCEDURE:
DATA TABLE:
+9CYY+ + +
BLOCK NUMBER
DATA
(2 digits)
EXE
ST
DE
+
+
DE
(1-16 digits)
: Default
NOTE: This data can be assigned by PCPro, not by CAT.
Continued on next page
Y 1ST DATA SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
00 Block number
assignment with
Function key
00
99
Block number FXXXX
NONE
Function key (Same as
F0XXX, F1XXX, F50XX
of CM90)
No data
CM90 Y=00:
FXXXX
01 Function Name
assignment with
character code
XXX...X
NONE
Character Code (Maxi-
mum 16 digits)
See Character Code Table.
Page 3-502
No data
02 Function Name
assignment with
character
XXX...X
NONE
Character (Maximum 8
digits)
No data
05 Function Name
assignment with
character (for Sim-
plified Chinese)
[8300R7] [Asia]
NOTE
XXX...X
NONE
Character (Maximum 4
characters; 8 digits)
No data
~
JANUARY/31/2012
CM9C

Table of Contents

Other manuals for NEC Univerge SV8300

Related product manuals