EasyManua.ls Logo

NEC Univerge SV8300 - [Cma7] Ccis Channel;Ip Trunk;Sip Trunk Data

NEC Univerge SV8300
804 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-573 NWA-033623-001 Rev.8.1
91ch3007.fm
COMMAND CODE
TITLE:
CCIS CHANNEL/IP TRUNK/SIP TRUNK DATA 1
A7
FUNCTION:
This command is used to assign the various data to each Common Channel Handler (CCH), IP Trunk
and SIP Trunk provided.
PRECAUTION:
When setting the IPT (P2P CCIS) No. with this command, be sure to set the first data to “00”.
ASSIGNMENT PROCEDURE:
DATA TABLE:
CCIS CHANNEL DATA
ST
EXE++ +
+
A7YY
DATA
DE
CCH/IPT/SIP TRUNK No. (00-15)
(1-5 digits)
++
DE
: Default
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
00 Trunk used as Common Signaling
channel/IPT (P2P CCIS)/SIP trunk
000
511
NONE
Trunk number assigned by CM10
Y=00
No data
CM10 Y=00
01 Originating Point Code (OPC) 00001
16367
NONE
Originating Point Code
No data
NOTE 1: The Originating Point Code is used to designate an originating office in the No. 7 CCIS network.
A single OPC should be assigned to IPT No. 0 and all other IPT (P2P CCIS) provided in the same
office.
NOTE 2: Do not change this data while the system is operating. If you do that, the operation of IP Stations
will be unstable.
Continued on next page
~
RESET
~