EasyManua.ls Logo

NEC Univerge SV8300 - [Cm61] External Key Function

NEC Univerge SV8300
804 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-440 NWA-033623-001 Rev.8.1
91ch3005.fm
COMMAND CODE
TITLE:
EXTERNAL KEY FUNCTION
61
FUNCTION:
This command is used to activate and specify the function of the switch closure detection PGD(2)-U10
ADP when interfaced with external keys.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST
EXE++ +
+
61YY
DATA
DE
KEY NUMBER
(3 digits) (1-2 digits)
++
DE
: Default
Y KEY NUMBER SETTING DATA
RELATED
COMMAND
No. MEANING No. MEANING DATA MEANING
00 Destination of Tenant XX Z XX: Key Group No.
(00-63) assigned by
CM12 Y=66
Z : Circuit No. (0/1)
00
63
NONE
Tenant 00
Tenant 63
No data
01 Change Day/Night trunk
restriction class by external
key
0
1
Effective
Ineffective
CM12 Y=01
03 Outgoing call restriction
on Night Mode by external
key
0
1
Effective
Ineffective
CM30 Y=08
05 Day/Night Mode change
by external key
0
1
Effective
Ineffective
CM30 Y=02,
03, 04, 05,
13, 14, 26
CM76 Y=01,
02
CM58
Y=02>09
06 Even if station-to-station
call is restricted, calling
tenant is allowed to cancel
restriction by external key
0
1
Effective
Ineffective
CM63 Y=1
Continued on next page
~
~
NOVEMBER/12/2008
CM61

Table of Contents

Other manuals for NEC Univerge SV8300

Related product manuals