3-150 NWA-033623-001 Rev.8.1
91ch3002.fm
COMMAND CODE
TITLE:
STATION NUMBER, TRUNK NUMBER, BLADE NUMBER
10
Setting method of Port number/Station number in Dual port mode
When using Analog Port Adapter and PGD(2)-U10 ADP in Dual port mode NOTE 1, the Circuit
numbers (17-32) of the DLC blade slot which accommodate Digital Multiline terminal/PGD(2)-
U10 ADP are used for the virtual station. Therefore, the virtual station number for Single Line
Telephone/PGD(2)-U10 ADP need to be registered to the Circuit numbers (17-32). Then, match
the Circuit numbers (01-16) of the physical station and the Circuit numbers (17-32) of the virtual
station (see figure below). For example, the Circuit number 17 corresponds to Single Line Tele-
phone connected to the Circuit number 01 of Digital Multiline Terminal.
Example:
• CM10 Y=00>010101: F200 (Station number of Digital Multiline Terminal)
• CM10 Y=00>010117: F300 (Station number of Single Line Telephone)
NOTE 1: When 2 Paging equipment are connected to a PGD(2)-U10 ADP, the setting of Dual port
mode is required as with Analog Port Adapter (related command: CM13 Y=32/33/34).
NOTE 2: The virtual station needs system capacity licenses only for the number of ports to be used.
Even when the virtual station is not connected, to just set the data for Dual port mode be-
comes the subject of license.
Continued on next page
Circuit number=01-16 Physical station
DLC blade
Circuit number=17-32 Virtual station
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Connection
Digital Multiline Terminal/
Station number of
PGD(2)-U10 ADP
Single Line Telephone/
Virtual station number of
PGD(2)-U10 ADP
JULY/17/2009
CM10