: Default
Y STATION NUMBER (A) SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
1 Pilot station in
ACD/UCD group
X
XXXXXXXX
Station number to
be assigned as Pilot
0
1
Member station
Pilot station
CM17 Y=0
Pilot station and
Member station for
OAI SCF
X
XXXXXXXX
Station number to
be assigned to queu-
ing for SCF
2
3
OAI Member
station (Off Hook
suppressed)
OAI Pilot station
(Monitor Pilot)
2 ACD/UCD Group
number
X
XXXXXXXX
Pilot and Member
station numbers
00
15
ACD/UCD group 00
ACD/UCD group 15
[8300R5 or
before]
CM17 Y=0
00
99
ACD/UCD group 00
ACD/UCD group 99
[8300R6 or later]
NONE No data
3 Display of station
numbers included in
ACD/UCD group
(Display only)
X
XXXXXXXX
Station number (A) X
XXXXXXXX
Station number (B)
(Display only)
CM17 Y=0
NOTE: In CAT mode, the displaying station number is added 1 with every press of the S (Step forward) key
regardless of the ACD/UCD group. In Command Mode of PCPro, the next station number in the ACD/
UCD group is displayed with every press of S (Step forward) key.
4 ACD/UCD service
for internal call
X
XXXXXXXX
Pilot station
number of ACD/
UCD group
0
1
Not provided
To provide
CM17 Y=1
5 ACD/UCD service
for C.O./DID
incoming call
X
XXXXXXXX
Pilot station
number of ACD/
UCD group
0
1
Not provided
To provide
CM17 Y=1
Continued on next page