Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
00 Authorization
Code per station
X
XXXXXXXX
Station number
(Maximum 8
digits)
X
XXXXXXXX
CCC
NONE
Authorization Code
(Maximum 8 digits)
X: 0-9, A (*), B (#)
Clear
No data
IP Station regis-
tration password
for Protected
Login Mode
X
XXXXXXXX
NONE
Password
(Maximum 8 digits)
X: 0-9, A (*), B (#)
No data
CM08>513
CM15 Y=480
Station Digest
Authentication
password
X
XXXXXXXX
NONE
Password
(Maximum 8 digits)
X: 0-9, A (*), B (#)
No data
Standard SIP
Station registra-
tion password
X
XXXXXXXX
NONE
Password
(Maximum 8 digits)
X: 0-9, A (*), B (#)
No data
NOTE 1: When the default is set to “NONE”, the password is set to “0000”.
NOTE 2: After assigning this command while SIP server is operating, be sure to report changing the SIP server
assigned by CM1D Y=33 second data “1”.
NOTE 3: The number of digits of the second data depends on the setting of CM42>73.
NOTE 4: To let the Standard SIP station function when no data is set for a digest authentication (such as conduct-
ing test operation by maintenance personnel), set “0000” (4 digits) as a password regardless of the set-
ting of CM42>73.
NOTE 5: The setting of Standard SIP station number is not available when originating/terminating a call or dur-
ing a call (“WAIT, BUSY NOW” is displayed).
NOTE 6: Be sure to reset Standard SIP station when this data setting is changed.
Continued on next page