3-274 NWA-033623-001 Rev.8.1
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
: Default
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
A 16 Sending ACK-WINK signal to DTI on
receiving MF signal
[North America Only]
0
1
To send
Not sent
NOTE: When the signal pattern from T1 network is FGD format, assign the data to “0”.
When the signal pattern from T1 network is ANI format, assign the data “1”.
17 Signal kind of called number sent from T1
network
[North America Only]
0
1
DP
DTMF
NOTE: When the signal pattern from T1 network is FGD format, assign the data to “1”.
When the signal pattern from T1 network is ANI format, assign the data “0”.
18 Sending of ACK-WINK signal to DTI on
receiving DP signal
[North America Only]
0
1
To send
Not sent
NOTE: When the signal pattern from T-1 network is FGD format, assign the data to “1”.
When the signal pattern from T-1 network is ANI format, assign “0”.
30 Tone level of MFC (Forward Signal/Back-
ward Signal)
[8300R3.5]
01
90
91
92
97
NONE
-45 dB
Increment unit: 0.5 dB
-0.5 dB
0 dB
+0.5 dB
Increment unit: 0.5 dB
+3 dB
-7.0 dB
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.
31 Tone Duration (On time) of MFC (Forward
Signal/Backward Signal)
[8300R3.5]
01
98
99
NONE
20 ms.
Increment unit: 20 ms.
1960 ms.
5100 ms.
100 ms.
NOTE: A reset by CM31 Y=A>90: 0 is required after this data setting.