No. MEANING DATA MEANING
295 Setting of PAD data from a
trunk to a conference trunk
(Effective for LDT/ODT/
PRT/DTI/CCT/SIP/IPT
[P2P CCIS])
[8300R3]
00
44
45
46
63
NONE
-45 dB
(1 dB increment)
-1 dB
0 dB
+1 dB
(1 dB increment)
+18 dB
See CM42>191
+: Gain
-: Loss
296 Setting of PAD data from a
conference trunk to a trunk
(Effective for LDT/ODT/
PRT/DTI/CCT/SIP/IPT
[P2P CCIS])
[8300R3]
01
15
16
17
31
NONE
-15 dB
(1 dB increment)
-1 dB
0 dB
+1 dB
(1 dB increment)
+15 dB
0 dB
+: Gain
-: Loss
297 Setting of PAD data from a
trunk to a DTMF Receiver
(Effective for COT/LDT/
ODT/BRT/PRT/DTI)
[8300R4]
00
44
45
46
63
NONE
-45 dB
(1 dB increment)
-1 dB
0 dB
+1 dB
(1 dB increment)
+18 dB
0 dB
+: Gain
-: Loss
298 Setting of DTMF Receiver
Type (Effective for COT/
LDT/ODT/BRT/PRT/DTI)
[8300R4]
0
1
2
NONE
Receiver Type 0 (For Station/Trunk)
Receiver Type 1 (As per CM45 Y=B)
Receiver Type 2 (As per CM45 Y=B)
Receiver Type 0 (For Station/Trunk)
CM45 Y=B
Continued on next page