3-330 NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE
TITLE:
FUNCTION OF CPU RS-232C PORT
40
PRECAUTION:
(1) The condition of connecting PCPro to the RS-232C is as follows.
- When connecting PCPro to the RS-232C ports other than Unit01, the connection depends on the
data setting by the first data “0/1” (Port 1/Port 2 of Unit01) of CM40 Y=01-06.
- For maintenance of whole system, PCPro must be connected to RS-232C port of Unit01.
If PCPro is connected to RS-232C port of the Unit except Unit01, the system data can be changed
temporarily only in each Unit connecting the PCPro. When system data copy is executed under
normal mode, these changed data is overwritten with the system data of Unit01.
- For survival mode or off-line mode, the data setting such as MCI or external printer for PMS is
ineffective even if the system data for them is set by CM40 Y=00. In that case, PCPro can be
connected to RS-232C ports of each unit.
- For on-line mode, PCPro cannot be connected to the same RS-232C port which is already set the
system data such as MCI or external printer for PMS is set by CM40 Y=00.
(2) The equipment connected to RS-232C ports on Unit02-03 is available only for normal mode
(survival mode and off-line mode are not available).
(3) The port number setting by CM40 Y=00 is required when providing Individual Station Record by
CIS (the connection to RS-232C ports for the equipment is not required).
[8300R1 only]
ASSIGNMENT PROCEDURE:
ST EXE++ ++40YY
SETTING DATA
DE
PORT LOCATION NUMBER
(0/1/4-7) (1-8 digits)
++ DE
ST EXE++ ++4010
SETTING DATA
DE
1ST DATA
(1/2) (1-8 digits)
++ DE
JANUARY/31/2012
CM40