Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
2 58 COT Ground Starting
Timer
NONE 01 02 03 .............................................98 99
8 ms.
(01-98)
48 ms. 8 16 24 ............................................784 2040
59 OD Trunk Answer
Detect Time
NONE 01 02 03 .............................................98 99
20 ms.
(01-98)
60 ms. 20 40 60 ...........................................1960 2550
60 OD Trunk Release
Detect Timer
NONE 01 02 03 .............................................98 99
200 ms.
(01-98)
700 ms. 200 400 600 .........................................19600 25500
61 OD Trunk Termination
Detect Timer
NONE 01 02 03 .............................................98 99
20 ms.
(01-98)
100 ms. 20 40 60 ...........................................1960 2550
62 OD Trunk Wink signal
sending time for con-
nection check
NONE 01 02 03 .............................................98 99
20 ms.
(01-98)
200 ms. 20 40 60 ...........................................1960 2550
63 OD Trunk Delay
Signal Timer out
NONE 01 02 03 .............................................98 99
20 ms.
(01-98)
200 ms. 20 40 60 ...........................................1960 2550
64 LD Trunk Answer
Detect Timer
NONE 01 02 03 .............................................98 99
20 ms.
(01-98)
60 ms. 20 40 60 ...........................................1960 2550
65 LD Trunk Release
Detect Timer
NONE 01 02 03 .............................................98 99
200 ms.
(01-98)
700 ms. 200 400 600 .........................................19600 25500
66 LD Trunk Termination
Detect Timer
NONE 01 02 03 .............................................98 99
20 ms.
(01-98)
100 ms. 20 40 60 ...........................................1960 2550
Continued on next page