EasyManua.ls Logo

NEC Univerge SV8300 - Page 419

NEC Univerge SV8300
804 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-363 NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
3 30 Loop Current Detect
Timing for DTI
(E1 2 Mbps) trunk
[8300R3]
NONE 01 02 03 .............................................98 99
16 ms.
(01-98)
48 ms. 16 32 48 ...........................................1568 4080
31 Clear Signal Detect
Timing for DTI
(E1 2 Mbps) trunk
[8300R3]
NONE 01 02 03 .............................................98 99
16 ms.
(01-98)
400 ms. 16 32 48 ...........................................1568 2040
32 DTI (E1 2 Mbps) trunk
Transmit clear signal
time for Forced
Release
[8300R3]
NONE 01 02 03 .............................................98 99
32 ms.
(01-98)
800 ms. 32 64 96 ...........................................3136 4080
33 DTI (E1 2 Mbps) trunk
Transmit Answer dura-
tion time
[8300R3]
NONE 01 02 03 .............................................98 99
16 ms.
(01-98)
304 ms. 16 32 48 ...........................................1568 2040
34 DTI (E1 2 Mbps) trunk
Transmit Double
Answer duration time
[8300R3]
NONE 01 02 03 .............................................98 99
128 ms.
(01-98)
2048 ms. 128 256 384 .........................................12544 16320
35 DTI (E1 2 Mbps) trunk
Receive Answer mini-
mum time
[8300R3]
NONE 01 02 03 .............................................98 99
16 ms.
(01-98)
200 ms. 16 32 48 ...........................................1568 2040
Continued on next page
BLADE RESET
BLADE RESET
BLADE RESET
BLADE RESET
BLADE RESET
BLADE RESET
JANUARY/14/2011
CM41

Table of Contents

Other manuals for NEC Univerge SV8300

Related product manuals