Y
1ST
DATA
MEANING
DEFAULT
2ND DATA
INCREMENT
UNIT
TIMER
3 51 DTI (E1 2Mbps) trunk
Transmit Seizure Sig-
nal time
[8300R3]
NONE 01 02 03 .............................................98 99
16 ms.
(01-98)
800 ms. 16 32 48 ...........................................1568 2040
60 MFC-R2 Backward
receiving guard timer
for DOD
[8300R3.5]
NONE 01 02 03 04 05 06 07 08
4 seconds
12
16
seconds
4 8 12 16 20 24 28 32
8 12162024283236
NOTE: This timer data is used as a guard timer when not detecting Backward signal from the opposite office.
61 MFC-R2 Backward
Tone Complete receiv-
ing guard timer for
DOD
[8300R3.5]
NONE 01 02 03 04 05 06 07 08
4 seconds
12
16
seconds
4 8 12 16 20 24 28 32
8 12162024283236
NOTE: This timer data is used as a guard timer when not detecting received Backward signal (end of tone)
from the opposite office.
62 MFC-R2 Forward
receiving guard timer
for DID
[8300R3.5]
NONE 01 02 03 04 05 06 07 08
4 seconds
12
16
seconds
4 8 12 16 20 24 28 32
8 12162024283236
NOTE: This timer data is used as a guard timer when not detecting Forward signal from the opposite office.
63 MFC-R2 Forward
Tone Complete receiv-
ing guard timer for
DID
[8300R3.5]
NONE 01 02 03 04 05 06 07 08
4 seconds
12
16
seconds
4 8 12 16 20 24 28 32
8 12162024283236
NOTE: This timer data is used as a guard timer when not detecting received Forward signal (end of tone)
from the opposite office.