3-371 NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM COUNTER DATA/PAD DATA
42
: Default
KIND OF SYSTEM COUNTER/PAD DATA SETTING DATA REMARKS
68 Volume Control (Side tone level) of Multiline
Terminal/DESKCON
00
06
NONE
–54 dB
–18 dB
–30 dB
NOTE 1: Do not change this data normally, incorrect data settings may cause howler of low-level speech.
NOTE 2: For the volume control (Side tone level) of DT300/DT700 series, set the data by CM42>198.
69 Call charge per unit for AOC
(dollar/euro/integral charge per unit)
[Australia/France/Germany/Nether-
lands/Italy/Greece/Luxembourg/Por-
tugal/Spain/Sweden/ITU-T (UAE)]
00
99
NONE
00-99 dollars/euro/integral
charge per unit
No data
70 Call charge per unit for AOC
(cent/euro cent/two decimals charge per unit)
[Australia/France/Germany/Nether-
lands/Italy/Greece/Luxembourg/Por-
tugal/Spain/Sweden/ITU-T (UAE)]
00
99
NONE
00-99 cents/euro cents/two
decimals charge per unit
No data
72 Number of times of Multiple Call Forward-
ing-All Calls/Busy Line/No Answer-CCIS
01
07
NONE
1 time
7 times
5 times
73 Number of digits for Station Authorization
Code/IP Station Password/Standard SIP
registration password
01
08
NONE
1 digit
8 digits
4 digits
CM2B Y=00
CM20 Y=0-3:
A230, A231
74 Off Hook Ring Volume 1 00
01
02
03
04
05
06
07
NONE
–10 dB
–12 dB
–14 dB
–16 dB
–18 dB
–20 dB
–22 dB
–24 dB
–20 dB
CM15 Y=205
75 Off Hook Ring Volume 2
77 Number of digits for the abbreviated code of
System Speed Dialing origination
01
08
NONE
1 digit
8 digits
4 digits
CM20 Y=0-3: A243
CM74 Y=5
Continued on next page
~
6 dB
increments
~
~
~
~
~
~
~
~
~
JANUARY/31/2012
CM42