: Default
YMEANING
1ST
DATA
MEANING 2ND DATA MEANING
6 Time setting for IP
Station firmware auto-
matic update
00 IP Station firmware
automatic update time
YYYY MM DD HH mm
NONE
YYYY: Year (2011-2099)
MM : Month (01-12)
DD : Day (01-31)
HH : Hour (00-23)
mm : Minutes (00-59)
No data
NOTE: This data is recommended to set to have two minutes or longer interval of time from the system clock.
7 Start time for copying
the system data from
the Main Unit to
Remote Units
00 System data copy HH MM
9999
NONE
HH : Hour (00-23)
MM : Minute (00-59)
Not copy the system data
automatically
0200 (2:00 a.m.)
NOTE 1: System data copy is executed from the low Remote Unit number to high Remote Unit number.
NOTE 2: The start time for system data copy may gain/loss about three minutes from the time you set.
8 Time setting for
Automatic clock
change
00 Time setting for
automatic system clock
change from standard
time to daylight-saving
time
(for change pattern 0)
MM W D
NONE
MM: Change Month (01-12)
W : Change Week (1-4/9)
First-Fourth Week
(1-4)
Final Week (9)
D : Change Day of the
week (0-6)
0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
Automatic clock change is
not provided
01 Time setting for auto-
matic system clock
change from daylight-
saving time to standard
time
(for change pattern 0)
Continued on next page