3-386 NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE
TITLE:
EXTERNAL RELAY STARTING CONDITIONS
44
The following table shows the interface condition of each external relay.
EQUIPMENT KIND INTERFACE RELATED COMMAND REMARKS
External Tone Source
[8300R3]
DLC + PGD(2)-U10 ADP CM05 Y=0
CM10 Y=00
CM12 Y=65: 3
CM13 Y=32-34, 63
CM44 Y=00: 02XX
CM44 Y=01
CM48 Y=0: 1300
CM64 Y=1
Start by External Relay Control
Circuit of PGD(2)-U10 ADP
RCA connector of PGD(2)-U10
ADP for tone
Wake Up Call/Timed
Reminder tone source
[8300R3]
DLC + PGD(2)-U10 ADP CM05 Y=0
CM10 Y=00
CM12 Y=65: 3
CM13 Y=32-34, 63
CM44 Y=00: 0100
CM44 Y=01
CM48 Y=1>00: 0200
Start by External Relay Control
Circuit of PGD(2)-U10 ADP
RCA connector of PGD(2)-U10
ADP for tone
Speaker Paging DLC + PGD(2)-U10 ADP CM05 Y=0
CM10 Y=00
CM12 Y=65: 1
CM12 Y=67, 68
CM13 Y=32, 33, 34, 63
CM20 Y=0-3: A070-
A079
CM44 Y=00: 02XX
CM44 Y=01
Start by External Relay Control
Circuit of PGD(2)-U10 ADP
RCA connector of PGD(2)-U10
ADP for tone
Indication for Trunk All
Busy
DLC + PGD(2)-U10 ADP CM05 Y=0
CM10 Y=00
CM12 Y=65: 3
CM13 Y=63
CM30 Y=09, 20-26
CM44 Y=00: 11XX
CM44 Y=01
CM54 Y=0
CM55 Y=0
Start by External Relay Control
Circuit of PGD(2)-U10 ADP
Continued on next page