3-390 NWA-033623-001 Rev.8.1
91ch3004.fm
COMMAND CODE
TITLE:
MAKE BUSY CONDITION OF CFT/DTMF RECEIVER DETECT LEVEL
45
: Default
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
B Setting of DTMF
Receiver detect level
(Related command:
CM15 Y=406, CM35
Y=298)
[8300R4]
X 00 Receiver start delay time
X: Receiver Type (0-2)
00
98
99
NONE
0 ms.
(0.25 ms. increments)
24.5 ms.
64 ms.
0 ms.
X 01 DTMF receiver detect level
X: Receiver Type (0-2)
00
01
02
03
04
05
06
NONE
Detect Level 0 (0- -25 dBm)
Detect Level 1 (-5- -30 dBm)
Detect Level 2 (-10- -35 dBm)
Detect Level 3 (-15- -40 dBm)
Detect Level 4 (-20- -45 dBm)
Detect Level 5 (-25- -50 dBm)
Detect Level 6 (-30- -55 dBm)
Detect Level 0 (0- -25 dBm)
X 02 Forward signal receiver
minimum detect level
(For Detect Level 0/1/2/3/4/
5/6)
X: Receiver Type (0-2)
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
NONE
-10/-15/-20/-25/-30/-35/-40 dBm
-11/-16/-21/-26/-31/-36/-41 dBm
-12/-17/-22/-27/-32/-37/-42 dBm
-13/-18/-23/-28/-33/-38/-43 dBm
-14/-19/-24/-29/-34/-39/-44 dBm
-15/-20/-25/-30/-35/-40/-45 dBm
-16/-21/-26/-31/-36/-41/-46 dBm
-17/-22/-27/-32/-37/-42/-47 dBm
-18/-23/-28/-33/-38/-43/-48 dBm
-19/-24/-29/-34/-39/-44/-49 dBm
-20/-25/-30/-35/-40/-45/-50 dBm
-21/-26/-31/-36/-41/-46/-51 dBm
-22/-27/-32/-37/-42/-47/-52 dBm
-23/-28/-33/-38/-43/-48/-53 dBm
-24/-29/-34/-39/-44/-49/-54 dBm
-25/-30/-35/-40/-45/-50/-55 dBm
-25/-30/-35/-40/-45/-50/-55 dBm