3-497 NWA-033623-001 Rev.8.1
91ch3005.fm
COMMAND CODE
TITLE:
DIGIT CONVERSION ON DID CALL
76
Data settings for Day/Night/A/B Mode Distinction of tenant
An explanation of tenant selection method for Day/Night/A/B Mode change, when DID call ter-
minates, is shown below as a tree diagram for system data registration.
(1) When station tenant for each DID number is assigned.
(CM76 Y=09 is set)
Continued on next page
CM76 Y=09
Station Tenant
for each DID No.
Mode of Station Tenant
for each DID No.
1
Data
Not
Set
Terminating Trunk Tenant
DAY/NIGHT/A/B Mode change
Data Set
DAY
NIGHT
A
B
CM76
Y=01
Other terminating
method
TAS
D13
For each terminating method
STA
DXX
00~63
Trunk Tenant set by
CM76 Y=18
Station Tenant for each
DID No.
NONE
00~63
Trunk Tenant set by
CM76 Y=05
Station Tenant for each
DID No.
NONE
CM76
Y=02
Other terminating
method
TAS
D13
For each terminating method
STA
DXX
00~63
Trunk Tenant set by
CM76 Y=19
Station Tenant for each
DID No.
NONE
00~63
Trunk Tenant set by
CM76 Y=06
Station Tenant for each
DID No.
NONE
CM76
Y=03
Other terminating
method
TAS
D13
For each terminating method
STA
DXX
00~63
Trunk Tenant set by
CM76 Y=20
Station Tenant for each
DID No.
NONE
00~63
Trunk Tenant set by
CM76 Y=07
Station Tenant for each
DID No.
NONE
CM76
Y=04
Other terminating
method
TAS
D13
For each terminating method
STA
DXX
00~63
Terminates at station set by
CM76 Y=21
Station Tenant for each
DID No.
NONE
00~63
Terminates at station set by
CM76 Y=08
Station Tenant for each
DID No.
NONE
JULY/17/2009
CM76