3-522 NWA-033623-001 Rev.8.1
91ch3005.fm
COMMAND CODE
TITLE:
LCR DEVELOPMENT TABLE
8A
: Default
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
5000
5255
LCR Pattern No. 000
LCR Pattern No. 255
164 Call by Call
WATS Ba nd Nu mb er
[North America Only]
00
09
NONE
WATS Ba nd Nu mb er
No data
165 Caller ID on outgoing
call by CCIS/Q-SIG/SIP
0
1
To add
Not added
166 911 Notification on
DESKCON/Multiline
Terminal
[North America Only]
0
1
To provide
Not provided
167 IP Address Pattern
See CM5B, CMBA
000
255
NONE
IP Address Pattern No. 000
IP Address Pattern No. 255
No data
NOTE: Set this command only for Point-to-Multipoint connection (when
CMA7 Y=46 is set to “0”).
168 Destination Point Code
(DPC) for IPT (P2P
CCIS)/SIP Point-to-Multi-
point connection
00001
16367
NONE
DPC
No data
NOTE 1: Set this command only for Point-to-Multipoint connection (when
CMA7 Y=46 is set to “0”).
NOTE 2: Don’t set the same DPC to two or more LCR Pattern number.
If the same DPC is set, some of CCIS Service (Attendant Camp-On
with Tone Indication-CCIS etc.) does not operate.
170 Echo canceller for SIP
trunk Point-to-Multi-
point connection
0
1
NONE
Echo canceller OFF
Echo canceller ON
No data
NOTE: Set this data when setting the echo canceller to each oppo-
site office respectively.