3-535 NWA-033623-001 Rev.8.1
91ch3006.fm
COMMAND CODE
TITLE:
MULTILINE TERMINAL KEY ASSIGNMENT
90
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
00 Setting of Functions F0XXX Service access code
XXX
040: Message Waiting Lamp Set (MWS)
041: Message Waiting Lamp Reset
(MWR)
CM15 Y=024
044: ACD/UCD Busy out (UCDB)
046: Call Hold (CHLD) CM15 Y=001
047: TAS Answer A (TASA)
048: TAS Answer B (TASB)
049: TAS Answer C (TASC)
050: TAS Answer D (TASD)
051: TAS Answer E (TASE)
CM53
058: (HOLD) for Trunk Line
Appearance
059: Trunk Answer
067: System Speed Dialing (300 memory)
068: System Speed Dialing for 1000
memories (1000-Slot Memory Block
No. 02)
069: Last Number Redial (LAST) CM08>177
085: Account Code (ACC) CM15 Y=030
097: Direct Data Entry
100: Trunk Route 00
163: Trunk Route 63
200: Route Advance 00
231: Route Advance 31
300: Operator Call (OPR)
[8300R2]
Continued on next page