3-7 NWA-033623-001 Rev.8.1
91ch3001.fm
COMMAND CODE
TITLE:
SETTING OF SYSTEM CLOCK/READING OUT OF DAYLIGHT
SAVING TIME
02
DATA TABLE:
: Default
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
0 Setting of Calendar Year YYYY
2000
Calendar Year
YYYY: Year (2011-2099)
2000
1 Setting of Date (Month, Day, Day of Week) MMDDWW
010106
Date
MM: Month (01-12)
DD : Day (01-31)
WW: Day of Week (00-06)
SUN : 00 THU: 04
MON: 01 FRI : 05
TUE : 02 SAT : 06
WED: 03
January/01 SAT
NOTE: Readout data of this data is displayed as “MM/DD WWW” (for example, this data is set to default,
readout data is displayed as “01/01 SAT”).
2 Setting of Time (Hour, Minute, Second)
“Hour” information is set in military format
(24-hour)
Example: 2 p.m. is set as “140000”.
HHMMSS
000000
Time
HH : Hour (00-23)
MM: Minute (00-59)
SS : Second (00-59)
00:00:00
NOTE: Readout data of this data is displayed as “HH:MM:SS” (for example, this data is set to default,
readout data is displayed as “00:00:00”).
3 Reading out of Daylight Saving Time of
Main Unit
HH:MM:SS
NONE
Daylight Saving Time
HH : Hour (00-23)
MM: Minute (00-59)
SS : Second (00-59)
No data
Continued on next page
JANUARY/31/2012
CM02