Loading...
3-585 NWA-033623-001 Rev.8.1
91ch3007.fm
COMMAND CODE
TITLE:
DTI/BRT/PRT/CCT BLADE FUNCTIONS
AA
: Default
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
22 Local loopback setting for BRT/
PRT (T1 1.5 Mbps/E1 2 Mbps)
(For test)
0
1
2
3
4
7
Local Loop Back (for BRT)
Remote Loop Back for PRT (FIFO
unavailable)
Payload Loop Back (for PRT)
(maintenance bit unavailable)
Remote Loop Back (for PRT)
(FIFO available)
Payload Loop Back (for PRT)
(maintenance bit available)
Loop Back OFF (for BRT/PRT)
CM05 Y=1
24 Local loopback setting for CCT (T1
1.5 Mbps/E1 2 Mbps)
(For test)
00
01
15
Local Loop Back
Payload Loop Back
Loop Back OFF
CM05 Y=1
25 Type of trunk for DTI (E1 2 Mbps)
[8300R3]
08
15
Brazil Code for collect call block-
ing trunk
[Brazil Only]
ITU-T Q.421 Standard trunk
CM05 Y=1
32 Sending RAI for CRC error
[For EU]
[8300R5]
0
1
Not sent
To send
CM05 Y=1
BLADE RESET
JUNE/15/2011
CMAA