Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
0 Firmware
download
XX ZZ XX: Unit number
(01-50)
ZZ : Slot number
(01-18)
XX YY ZZ Readout data of firmware
when operating
XX: Firmware type (Same as
second data of CM05
Y=0)
YY: Firmware version on the
blade
ZZ : Firmware version of the
blade supplied with the
basic software
CM05 Y=0
XX Input data when executing
download
XX: Firmware type to down-
load (same for the sec-
ond data of CM05 Y=0)
NOTE 1: The appropriate access blade is reset when executing download, then
the firmware update starts. The cycle of the Live LED becomes special
cycle during updating.
NOTE 2: After the firmware update is completed, the access blade is reset auto-
matically and activated.
NOTE 3: Refer to the “PC Programming Manual” for the operating procedure
to update the blade firmware program.
2 Read the status of
firmware download
XX ZZ XX: Unit number
(01-50)
ZZ : Slot number
(01-18)
FFFF Download is completed
(normal end)
CM05 Y=0
Continued on next page