3-679 NWA-033623-001 Rev.8.1
91ch3008.fm
COMMAND CODE
TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
NOTE 1: When the fault kind No. 022 is applied to IPT (P2P CCIS), the fault message means “IPT
link connection failure”.
NOTE 2: The fault kind No. 062 is effective only for PZ-64IPLC-A/PZ-128IPLC-A.
FAULT KIND NUMBER FAULT CONTENT
106 SV8300 Blade reset with CME03
107 Lack of option value
108 Lack of Highway Channel
109 Auto Blade Reset by TDM-Blade Lockup
10A CPU SRAM failure
10B Restricted blade
10C Firmware version un-matching between CPU blade and Line/Trunk blade
10D Lack of Highway Channel for data communication
10E Illegal use of CPU blade for Remote Unit only
110 Communication error occurrence between active CPU and stand by CPU
112 Expansion Chassis (2U) failure
114 Automatic module reset due to Expansion Chassis (2U) lockup
115 Automatic system reset due to Expansion Chassis (2U) lockup
116 All blades lockup in Expansion Chassis (2U)
11A Communication error occurrence between Primary Unit and Secondary Unit
11C Internal BUS failure on CPU Blade
11E Restriction of Remote Maintenance via built-in modem