3-701 NWA-033623-001 Rev.8.1
91ch3008.fm
COMMAND CODE
TITLE:
HIGHWAY CHANNEL MEMORY READ/REASSIGNMENT
F7
CMF7 Y=9
CMF7 Y=9 is the command which reassigns the high way channel (128ch) allocation to each physical
slot (slot1-6/7-12/13-18). For the physical slot, 16 channels are allocated to each slot in reset state
(the high way channel allocation is in a state which is not reassigned before).
When more than 17 channels are needed for adding blades, high way channel must be reassigned by
this command (when high way channel number is not reassigned, the channel numbers from the chan-
nel No.17 cannot be used).
NOTE: After setting this command, Blade Reset is required for all the physical slots of the desired
highway channel by CME0 Y=3.