Introduction......................................................................................................................................................................1
Materials..........................................................................................................................................................................3
Supported Web Browsers ...............................................................................................................................................4
Features And Functions ..................................................................................................................................................5
Installation .......................................................................................................................................................................7
Mounting Instructions-16D...........................................................................................................................................7
Mounting Instructions-5D / -2D....................................................................................................................................8
DIN Rail Mounting.....................................................................................................................................................9
Sensor Attachment .................................................................................................................................................10
RJ45 Sensor Ports..................................................................................................................................................10
Digital In Terminals.................................................................................................................................................11
Liquid Detection Sensors........................................................................................................................................11
Alarm(Beacon/Siren) Connections .........................................................................................................................13
Connect Output Devices............................................................................................................................................14
Terminal Connection for RS232 ................................................................................................................................15
Ethernet Connection for Remote User Control..........................................................................................................16
Modem Connection....................................................................................................................................................17
USB GSM Modem ..................................................................................................................................................17
SMS Relay Via SNMP ............................................................................................................................................18
Serial GSM Modem.................................................................................................................................................19
Power Connection-E-16D..........................................................................................................................................20
Dual Power Option..................................................................................................................................................20
DC Power Option....................................................................................................................................................21
Power Connection- E-5D/-2D....................................................................................................................................21
Remote RS232 Device Control...............................................................................................................................23
Overview - Use And Operation......................................................................................................................................25
Sensors...................................................................................................................................................................25
IP Assignment.........................................................................................................................................................25
User Management ..................................................................................................................................................25
Alerts.......................................................................................................................................................................25
Data and Event Logging .........................................................................................................................................26
Email.......................................................................................................................................................................26
Syslog .....................................................................................................................................................................26
SNMP......................................................................................................................................................................26
SNMP Sensors .......................................................................................................................................................26
Modbus TCP/IP Support.........................................................................................................................................26
External Modem......................................................................................................................................................26
Power-on/Reset Operation .....................................................................................................................................26
Out-of-Box Operation..............................................................................................................................................27
Expandability...........................................................................................................................................................27
Device Discovery Tool...................................................................................................................................................28
How to Use the Device Discovery Tool .....................................................................................................................28
Use and Operation via Web Interface...........................................................................................................................29
Log In and Enter Password .......................................................................................................................................29
Monitoring..................................................................................................................................................................30

Table of Contents

Other manuals for NTI ENVIROMUX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NTI ENVIROMUX Series and is the answer not in the manual?

NTI ENVIROMUX Series Specifications

General IconGeneral
Product TypeEnvironmental Monitoring System
Temperature Range-40°C to 85°C
Power Supply12V DC or 24V AC
Network InterfaceEthernet 10/100 Mbps
Alarm NotificationsEmail, SNMP
Sensor Types SupportedTemperature, Humidity, Water, Airflow
Power12V DC or 24V AC
Operating Temperature-40°C to 85°C
MountingWall or Rack Mount
Communication InterfacesEthernet
Data LoggingYes
ComplianceCE, RoHS