Chapter 6
6-16
Message Communications
01
16 Speed scale Speed data unit selection
can be set and read. The
speed data unit value is
calculated as follows:
Unit = 1 [r/min] x 1/2
a
a: Speed scale set value
Set a negative value as its
2's complement.
15 to 15 (F1
to 0F hex)
00 Yes Yes Byte
17 Current scale Current data unit selection
can be set and read. The
current data unit value is
calculated as follows:
Unit = 0.1 [A] x 1/2
b
b: Current scale set
value
Set a negative value as its
2's complement.
15 to 15 (F1
to 0F hex)
00 Yes Yes Byte
1A Power scale Power data unit selection
can be set and read. The
power data unit value is
calculated as follows:
Unit = 1 [W] x 1/2
c
c: Power scale set value
Set a negative value as its
2's complement.
15 to 15 (F1
to 0F hex)
00 Yes Yes Byte
1B Voltage scale Voltage data unit selection
can be set and read. The
voltage data unit value is
calculated as follows:
Unit = 1 [V] x 1/2
d
d: Voltage scale set
value
Set a negative value as its
2's complement.
15 to 15 (F1
to 0F hex)
00 Yes Yes Byte
1C Time scale Time data unit selection
can be set and read. The
time data unit value is cal-
culated as follows:
Unit = 1 [ms] x 1/2
e
e: Voltage scale set
value
Set a negative value as its
2's complement.
15 to 15 (F1
to 0F hex)
00 Yes Yes Byte
1D Reference From
Net
(See note 1.)
00: Reference other than
DeviceNet (n004/b1-01)
01: Operating with
DeviceNet.
--- 00 Yes No Byte
64 Electric power Average power value (W) --- 0000
0000
Yes No Long
65 Electric power
time scale
Power value measure-
ment period (T) (reflected
when power is turned ON)
00: 10 minutes
01: 30 minutes
02: 60 minutes
00 to 02 00 Yes Yes Byte
6F Specific alarm Alarm code of the alarm or
minor fault detected in the
Inverter. For more details,
refer to 8-5 Inverter
Alarms.
--- 0000 Yes No Word
70 Specific error Fault code of the fault
detected in the Inverter.
For more details, refer to
8-4 Inverter Faults.
--- 00 Yes No Byte
Instance Attribute Name Content Setting range Default Read Write Size