Chapter 6
6-15
Message Communications
01
10 Input Voltage Can be referenced in
hexadecimal with the input
voltage setting (200 or
400/E1-01) minimum unit
as 1 V.
Setting the attribute 1B
voltage scale enables a
multiplication factor to be
set.
--- 0000 Yes No Word
11 Output Voltage Can be referenced in
hexadecimal with the out-
put voltage monitor U-04/
U1-06 minimum unit as 1
V.
Setting the attribute 1B
voltage scale enables a
multiplication factor to be
set.
--- 0000 Yes No Word
12 Accel Time Can be set and read in
hexadecimal with the
acceleration time 1 n019/
C1-01 and deceleration
time 1 n020/C1-02 mini-
mum unit as 1 ms.
Depending on the acceler-
ation/ deceleration time
unit n019/C1-10 setting,
numbers below 100 ms or
10 ms are truncated.
Setting the attribute 1C
time scale enables a mul-
tiplication factor to be set.
0.0 to
6,000.0 s
(0.00 to
600.00 s)
2710 hex
(10.0 s)
Ye s Ye s W o r d
13 Decel Time 2710 hex
(10.0 s)
Ye s Ye s W o r d
14 Low Speed Limit
(See notes 2
and 3.)
Can be set and read in
hexadecimal with the fre-
quency reference lower
limit n034/d2-02 and the
frequency reference upper
limit n033/d2-01 minimum
unit as 1 ms.
The minimum unit can be
set by the frequency refer-
ence setting and display
units in n035/o1-03.
n035/o1-03 = 0: 0.01 Hz
n035/o1-03 = 1: 0.01%
(100%: Max. frequency.)
n035/o1-03 = 2 to 39:
1r/min
n035/o1-03 = 40 to 3,999:
Follow individual set val-
ues.
When r/min units are
being used, a multiplier
can be set in attribute 16
(the Speed Scale setting).
0 to 109% of
maximum fre-
quency
0000 Yes Yes Word
15 High Speed
Limit
(See notes 2, 3,
and 4.)
0 to 110% of
maximum fre-
quency
0708 hex
(1,800 r/
min)
Ye s Ye s W o r d
Instance Attribute Name Content Setting range Default Read Write Size