Chapter 10
10-9
Appendices
01
Explicit
message
09 Expected packet
rate
Indicates the length of the
internal processing time-
out when a communica-
tions request is received.
Incremented by 10-ms
units.
0 to 65,535
(ms)
09C4
(2,500
ms)
Ye s Ye s W o r d
0C Watchdog time-
out action
Indicates the action for
internal processing time-
out related to communica-
tions.
00: Retain timeout status
(until reset or cleared).
01: Cut connection auto-
matically.
02: Operate again with
same connection as is.
--- 01 Yes No Byte
0D Produced con-
nection path
length
(No data for explicit mes-
sages.)
--- 0000 Yes No Word
0E Produced con-
nection path
(No data for explicit mes-
sages.)
--- --- Yes No Array
0F Consumed con-
nection path
length
(No data for explicit mes-
sages.)
--- 0000 Yes No Word
10 Consumed con-
nection path
(No data for explicit mes-
sages.)
--- --- Yes No Array
02
03
04
Remote
I/O
(See
note 2.)
01 State Indicates the status of this
object (instance).
00: Does not exist in net-
work, or is not ready.
01: In network state, wait-
ing for connection event
from Master Unit.
02: Waiting for connection
ID (attribute) writing.
03: Connection com-
pleted.
04: Timeout
--- Must be
“03" when
communi-
cations
are estab-
lished.
Ye s N o B y t e
02 Instance type Indicates the type of
object (instance).
00: Explicit message
01: Remote I/O
--- 01 Yes No Byte
03 Transport class
trigger
Indicates the communica-
tions configuration for the
DeviceNet Communica-
tions Unit/Card.
--- 82 Yes No Byte
04 Produced con-
nection ID
Indicates the label used
for the communications
header for the DeviceNet
Communications Unit/
Card. (See note 1.)
* These are set when the
communications con-
nection is made.
--- --- Yes No Word
05 Consumed con-
nection ID
--- --- Yes No Word
06 Initial comm
characteristics
Indicates the communica-
tions configuration for the
DeviceNet Communica-
tions Unit/Card.
--- 01 Yes No Byte
07 Produced con-
nection size
Indicates the maximum
number of bytes for trans-
mission.
--- See note
3.
Ye s N o W o r d
Instance Attribute Name Content Setting range Default Read Write Size