10-2-10AC/DC Drive Objects: Class 2A Hex
AC/DC drive objects are assigned to command-related functions for drive devices such as Inverters
and Servomotors. Command-related data reading and writing, monitor data reading, set data scale
changes, and so on, are all enabled. These functions are shared with similar functions used for
remote I/O, so even if they have been set for message operations they may get rewritten for remote I/
O.
Support Service Code
Object Details
4210 OH1 Overheat
5110 UV2 Control power supply fault
5120 PUF Fuse open
5300 OPR Operator disconnection
6320 ERR EEPROM write failure
7110 RR Braking transistor failure
7112 RH Braking resistor overheating
7301 PGO PG is disconnected
7310 OS Overspeed
DEV Speed deviation
7500 BUS Communications error
9000 EF3 External fault (Terminal 3)
EF4 External fault (Terminal 4)
EF5 External fault (Terminal 5)
EF6 External fault (Terminal 6)
EF7 External fault (Terminal 7)
EF8 External fault (Terminal 8)
FF0 Communications external fault
Service code number (hex) Service
0E Get attribute single
10 Set attribute single
Instance Attribute Name Content Setting range Default Read Write Size
00 01 Object Software
Revision
Indicates class 2A software
revisions. The revision
value is advanced when-
ever there is a change.
--- 0001 Yes No Word
01 03 At Reference 00: Stopped, accelerating
or decelerating
01: At reference
--- 00 Yes No Byte
04 Net Reference
(See note 1.)
00: Operate with setting in
n004/b1-01.
01: Force DeviceNet opera-
tion (not valid in 3G3FV).
00, 01 00 Yes Yes Byte
DeviceNet error code Operator display Meaning