Chapter 10
10-76
Appendices
Note 1. When the control mode is changed, the Inverter will revert to default settings. (The V/f control
default setting is given above.)
Note 2. The setting range depends on the capacity of the Inverter.
Note 3. These parameters can be monitored or set only when F is set for C6-02.
■ Reference Parameters
C4-01 0215 02 15 Torque compensation gain 0.00 to
2.50
0.01 1.00 Yes
C4-02 0216 02 16 Torque compensation pri-
mary delay time constant
0 to
10,000
1 ms 200
(See
note 1.)
No
C6-02 0224 02 24 Carrier frequency selection 1 to F 1 De-
pends
on ca-
pacity.
No
C6-03 0225 02 25 Carrier frequency upper
limit
2.0 to
15.0
(See
notes 2
and 3.)
0.1 kHz De-
pends
on ca-
pacity.
No
C6-04 0226 02 26 Carrier frequency lower limit 0.4 to
15.0
(See
notes 2
and 3.)
0.1 kHz De-
pends
on ca-
pacity.
No
C6-05 0227 02 27 Carrier frequency propor-
tional gain
00 to 99
(See
note 3.)
100No
Param-
eter
Register
No.
(Hex)
Class 64 (Hex) Name Setting
range
Setting
unit
Default
setting
Changes
during
opera-
tion
In-
stance
At-
tribute
d1-01 0280 02 80 Frequency reference 1 0 to
max.
output
fre-
quency
0.01 Hz
(Set
with o1-
03.)
0.00 Yes
d1-02 0281 02 81 Frequency reference 2 0.00 Yes
d1-03 0282 02 82 Frequency reference 3 0.00 Yes
d1-04 0283 02 83 Frequency reference 4 0.00 Yes
d1-17 0292 02 92 Jog frequency reference 6.00 Yes
d2-01 0289 02 89 Frequency reference upper
limit
0.0 to
110.0
0.1% 100.0 No
d2-02 028A 02 8A Frequency reference lower
limit
0.0 to
110.0
0.1% 0.0 No
d2-03 0293 02 93 Master speed reference
lower limit
0.0 to
110.0
0.1% 0.0 No
Param-
eter
Register
No.
(Hex)
Class 64 (Hex) Name Setting
range
Setting
unit
Default
setting
Changes
during
opera-
tion
In-
stance
At-
tribute