Chapter 10
10-77
Appendices
Motor Constant Parameters
d3-01 0294 02 94 Jump frequency 1 0.0 to
400.0
0.1 Hz 0.0 No
d3-02 0295 02 95 Jump frequency 2 0.1 Hz 0.0 No
d3-03 0296 02 96 Jump frequency 3 0.1 Hz 0.0 No
d3-04 0297 02 97 Jump frequency width 0.0 to
20.0
0.1 Hz 1.0 No
d6-01 02A0 02 A0 Field weakening level 0 to 100 1% 80 No
d6-02 02A1 02 A1 Field frequency 0.0 to
400.0
0.1 Hz 0.0 No
Param-
eter
Register
No.
(Hex)
Class 64 (Hex) Name Setting
range
Setting
unit
Default
setting
Changes
during
opera-
tion
In-
stance
At-
tribute
E1-01 0300 03 00 Input voltage setting 155 to
255
(155 to
510)
(See
note 1.)
1 V 200
(400)
(See
note 1.)
No
E1-03 0302 03 02 V/f pattern selection 0 to F
E can-
not be
set.
1FNo
E1-04 0303 03 03 Max. output frequency 0.0 to
120.0
0.1 Hz 50.0 No
E1-05 0304 03 04 Max. voltage 0.0 to
255.0
(0.0 to
510.0)
(See
note 1.)
0.1 V 200.0
(400.0)
(See
note 1.)
No
E1-06 0305 03 05 Base frequency 0.0 to
120.0
0.1 Hz 50.0 No
E1-07 0306 03 06 Mid. output frequency 0.0 to
120.0
0.1 Hz 3.0 No
E1-08 0307 03 07 Mid. output frequency volt-
age
0.0 to
255 (0.0
to
510.0)
(See
note 1.)
0.1 V 15.0
(30.0)
(See
note 1.)
No
E1-09 0308 03 08 Min. output frequency 0.0 to
120.0
0.1 Hz 1.5 No
Param-
eter
Register
No.
(Hex)
Class 64 (Hex) Name Setting
range
Setting
unit
Default
setting
Changes
during
opera-
tion
In-
stance
At-
tribute

Table of Contents

Related product manuals