Chapter 10
10-80
Appendices
Note 1. The values in parentheses indicate initial values when initialized in 3-wire sequence.
Note 2. Set H5-01 to 0 to disable Inverter responses to RS-422A/485 communications.
■ Protective Function Parameters
H4-01 041D 04 1D Monitor selection (terminal
FM)
1 to 40 1 2 No
H4-02 041E 04 1E Gain (terminal FM) 0.0 to
1,000.0
0.1% 100.0 Yes
H4-03 041F 04 1F Bias (terminal FM)
−110.0
to 110.0
0.1% 0.0 Yes
H4-04 0420 04 20 Monitor selection (terminal
AM)
1 to 40 1 3 No
H4-05 0421 04 21 Gain (terminal AM) 0.0 to
1,000.0
0.1% 50.0 Yes
H4-0604220422Bias (terminal AM)
−110.0
to 110.0
0.1% 0.0 Yes
H4-07 0423 04 23 Analog output 1 signal level
selection
0 or 2 1 0 No
H4-08 0424 04 24 Analog output 2 signal level
selection
0 or 2 1 0 No
H5-01 0425 04 25 Slave address 0 to 20
(See
note 2.)
11FNo
H5-02 0426 04 26 Communication speed
selection
0 to 4 1 3 No
H5-03 0427 04 27 Communication parity
selection
0 to 2 1 0 No
H5-04 0428 04 28 Stopping method after com-
munication error
0 to 3 1 3 No
H5-05 0429 04 29 Communication error detec-
tion selection
0 or 1 1 1 No
H5-06 042A 04 2A Send wait time 5 to 65 1 ms 5 No
H5-07 042B 04 2B RTS control ON/OFF 0 or 1 1 1 No
Param-
eter
Register
No.
(Hex)
Class 64 (Hex) Name Setting
range
Setting
unit
Default
setting
Changes
during
opera-
tion
In-
stance
At-
tribute
L1-01 0480 04 80 Motor protection selection 0 or 1 1 1 No
L1-02 0481 04 81 Motor protection time con-
stant
0.1 to
5.0
0.1 min 1.0 No
L1-03 0482 04 82 Alarm operation selection
during motor overheating
0 to 3 1 3 No
L1-04 0483 04 83 Motor overheating opera-
tion selection
0 to 2 1 1 No
L1-05 0484 04 84 Motor temperature input fil-
ter time constant
0.00 to
10.00
0.01 s 0.20 No
Param-
eter
Register
No.
(Hex)
Class 64 (Hex) Name Setting
range
Setting
unit
Default
setting
Changes
during
opera-
tion
In-
stance
At-
tribute