4 - 15
4 Setting the Controller
Vision System FH/FHV/FZ5 Series Users Manual (Z365)
4-4 Setting Operation Mode [Startup Settings]
4
4-4-1 Setting the Operation Mode
You can execute the measurement process with a multi-core CPU to inspect more measurement tar-
gets in less time than conventional processing would allow. This mode uses up to four CPU cores (or
eight threads) on a CPU that take turns in the execution of a single inspection flow every time the STEP
signal is input.
Refer to Multi-input Function on page 4-16.
Important
The transaction time for a single workpiece is shorter if parallel processing is enabled to
allow parallel execution of the measurement flow.
Refer to 4-4-2 Parallel Processing on page 4-29.
It is assumed that the [Double Speed multi-input] will be used together with the multi-input
function. Refer to Multi-input Function before you use the Double Speed Multi-input. When
the multi-input function cannot be used, the Double Speed Multi-input mode is not available.
Choose another mode than the Double Speed Multi-input mode.
Refer to Multi-input Function on page 4-16.
Certain processing items, such as Serial Output, Parallel Output, and Parallel Judgement
Output, may slow the performance of the Double Speed Multi-input mode if they are pro-
grammed in the first half of the flow. If the performance drops significantly, consider the use
of parallel processing.
Some processing items, such as Trend Monitor and Last NG Display, may not function cor-
rectly if Double Speed Multi-input is used. Do not use them. Calculation items that use the
numeric values from a previous STEP may not calculate correctly.
You cannot use Simplified Non-stop Adjustment Mode during Double Speed Multi-input.
External commands to obtain and set unit data will not operate correctly. Do not use them.
If you use external commands, the BUSY signal will remain ON during command execution
longer than for other operation modes.
Compared with other operation modes, it will take more time to perform processing which
includes screen transition, such as Scene switch, Scene group switch and Edit flow.